Bringing our boat up to ABYC ELCI standards
What is an ELCI"?
It's an Electrical Equipment Leakage Circuit Interrupter.
Quote:- "
The ABYC E-11 Standard (Boat Side)
According to standard ABYC E-11, any AC-powered vessel equipped with shore power should have an ELCI installed within 10 feet of the inlet (or use an isolation transformer within that same 10-foot distance). ELCIs are set to trip at 30 mA within 100 milliseconds to prevent electrical leakage from energizing the surrounding water and causing Electric Shock Drowning (ESD)"
That rule was implemented in July 2008 and required compliance was extended to July 31st 2010
Eximius does not have an ELCI in our Electrical System. We do have a Galvanic Isolator, but what is the difference between the two devices?
Gemini provided this comparison table.
| Feature | Galvanic Isolator | ELCI (Equipment Leakage Circuit Interrupter) |
| Primary Danger Avoided | Galvanic Corrosion (metal destruction) | Electric Shock Drowning (ESD) & Fire |
| Current Monitored | Low-voltage DC current (< 1.4V) | AC current imbalance between Hot & Neutral |
| What It Protects | Underwater metals (shafts, props, thru-hulls) | Human life and onboard electrical wiring |
| Action Taken | Blocks DC; stays connected | Trips the AC main breaker instantly |
| Location Installed | Inline on the green ground wire | On all AC conductors (Hot, Neutral, Ground) |
| Standard / Rule | ABYC A-28 | ABYC E-11 |
What it protects is the important difference.
How do we install the ELCI device.
There are several types that are suitable for 'small' boats like Eximius, some are part of a new panel and others are for insertion in an existing panel, there is another type that is an Inline ELCI specifically for boats with Smart Plug Shore power connections.
I'm going for the type to use in an existing panel.
After hours of trying to figure out how to modify the wiring in the electrical control panel in order to install this ELCI, I slept on it ( mentally, duh! )
In the middle of the night, I realized it would probably fit in the existing AC Disconnect & Reverse Polarity box under the Nav table.
But what are the dimensions? Will it fit? Will I need to run new wires for the AC inlet or for the wiring from the Disconnect box to the Victron Multiplus?
Asking Gemini didn't help as the dimensions it gave seemed wildly oversized and those would not allow the ELCI to fit in the existing Disconnect box.
So I called PKSY - they have always been a big help in the past, very professional without being snooty.
John from Tech support took my call and I explained what I was trying to do and that the dimensions on line were insufficient to allow me to determine if it would fit the space in my box.
John immediately picked upon my concern and had me hold on for a couple of minutes while he got his hands on the actual ELCI. Now my questions made more sense and he was able to satisfy my concerns.
He took a few pics of the unit and emailed them. He also explained how the spacers ( shown on the right side of the pic above ) can be folded ( bent ) out of the way. I responded that I figured those flaps were protection from creating a short between the Hot and Neutral wiring connections. Correct!
So, I think it will fit! Worse case scenario will require a new box, but that's not a big deal.
Here's a
link to my original diagram for the reverse polarity test switch which I installed June 23, 2022,
the update simply replaces the Shore Power Disconnect Switch 30Amp Circuit Breaker with the new ELCI
My only concern at this point is wondering if the Reverse Polarity Test Switch briefly connecting the Neutral to Ground via the Lamp Test Switch, will that trip the shore based ELCI if installed?
The ELCI is ordered, should arrive Thursday, this week. My expectation is that the upgrade will take about an hour. But then again, it's a boat!
The ELCI finally arrived 2 days late via USPS but it arrived!
One of the pics of the ELCI out of the box. Note how the 'wings' are partially folded.
This pic shows the Wire connections.
The wiring diagram shows that the 'pig tail' white wire should be connected to the Load Neutral terminal.
The Load 1 and N lines should pass through the sensor twisted together and held in place with a tie wrap.
The Hole for the push to test button is 1/2" diameter and the spacing
The Hole for the push to test button is 1/2" diameter and the spacing of the mounting holes for the push to test button match those of the breaker switches.
This view shows the sensor hole through which the Load 1 and Neutral lines have to pass.
The instructions that came with the package includes a complete wiring diagram that clarifies the connection of the Pig Tail.
Ok, time for the install.
It's a cramped area, but this is my Shore Power Disconnect and Reverse Polarity test box.
When I installed this Shore power disconnect, the Breakers "Up" is 'On'
The new ELCI breaker would have the Test button on the left of the existing breaker. Luckily, there is room for that between the double breaker and the Test switch.
Just for context, the Disconnect box is mounted beneath the Nav table and on the Forward face of bulkhead separating the cabin from the head.
This shows the inside of the Disconnect box, I did say it's cramped.
Releasing the wires from the breaker and the ground wire from the Reverse Polarity switch freed the front panel of the box.
It only took a few minutes to drill the holes required for the ELCI test button and the two mounting screws.
As I had considered, the wire from the Load side of the ELCI to the Victron Multiplus are about 3 or 4 inches short if they are to pass through the sensing ring of the ELCI. So I needed to stop here and bring some #10 3 wire Marine Cable as well as the ring terminals, heat shrink etc. Pretty sure I have some of that cable at home. Time to wrap up for today.
Ok, armed with the replacement 3 wire cable, yes, marine fine multistrand. I got to the boat and made good progress. Duh! I need 10/12 AWG #10 ring terminals. Another delay. They arrived a couple of days later. Now I really do have all the bits and pieces. Let's see if this project can be completed tomorrow.
Well that didn't go well!
I was able to make all of the 110v connections inside the AC Disconnect Box, "BUT" I could not close the box! Grrrrrr.
The terminal connections to the ELCI require that the wires exit towards the back of the device. So even though the ELCI fits neatly in the box, it will not fit when the wires are connected.
Back to the drawing board. I found this Electrical Project Box on Amazon. It's the same height & width of the existing box but nearly 2" deeper.
Should arrive this week.
Then I'll drill for the 110v inlet/outlet and the holes for the ELCI & the holes for the LED lamps for the Reverse Polarity tester.
At least another hour or two on the boat to get all of this done, but at least it'll be easy to install the ELCI with plenty of room.
Unless..... ( it is a boat after all )
Well, it's all done bar the Testing.
It took about an hour to drill all the holes in the new box.
The ELCI breaker was first, that required 3 x 1/2" holes for the breaker switches and the Test button and the 6 holes for the breaker mounting screws. Next was the holes for the Reverse Polarity Switch and two LEDs. Finally the hole for the 110v cables just visible on the Stbd side of the box in this pic.
With all the holes drilled next was to run the 100v wires through the cable gland. However, trying to connect those wires to the breaker terminals was not possible with the breaker installed I had to release the 6 mounting screws, connect the wires to the breaker then reinstall the breaker.
The deeper box made it easy to put the lid in place and soon after connecting the wires I was able to close up the box and move on the the connection to the Victron Mulitplus.
Now, all of this is being done at arms length beneath the Nav Table, that's not cramped, it's a testing ground for body flexibility.
With the 110v 'AC 1 In ' wires connected I tried to turn on the inverter.
Not happening! The menu option was not even available. Could it be that there is an Interlock that prevents the Inverter turning on when the Multiplus faceplate is not installed?
The Control menu was still not available when the faceplate was installed. Hmmm.
Time for a full system reboot. To that I just turned the battery bank off. Gave it a short coffee break and turned it back on.
WallAh! As always, it took the control display a couple of minutes to wake up, but as soon as I brought the Menu page up, I could see that the control options were back to normal.
I spent a couple of minutes checking that all looked well and then took that pic above and called it a day.
We've been out of town for a week and know that it rained a lot while were away. I checked the bilges, they were dirty but dry so the bilge pump is working well too.
After loading my 'work bag' with tools that I use both at home and on the boat, I closed up the cabin. Peggy asked if we could wash down the deck before leaving, of course!
Then, it's back home. I'll go back to the boat in a couple of days and connect shore power to test the new ELCI. Life is looking good.
See you on the water! Hopefully in a clean boat and under sail.
Paul